A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran
| dc.creator | Faridi, Sasan | |
| dc.creator | Niazi, Sadegh | |
| dc.creator | Sadeghi, Kaveh | |
| dc.creator | Naddaf, Kazem | |
| dc.creator | Yavarian, Jila | |
| dc.creator | Shamsipour, Mansour | |
| dc.creator | Shafiei Jandaghi, Nazanin Zahra | |
| dc.creator | Sadeghniiat, Khosro | |
| dc.creator | Nabizadeh, Ramin | |
| dc.creator | Yunesian, Masud | |
| dc.creator | Momeniha, Fatemeh | |
| dc.creator | Mokamel, Adel | |
| dc.creator | Sadegh Hassanvand, Mohammad | |
| dc.creator | MokhtariAzad, Talat | |
| dc.date.accessioned | 2020-08-03T19:32:32Z | |
| dc.date.available | 2020-08-03T19:32:32Z | |
| dc.date.created | 2020 | |
| dc.description.abstract | The coronavirus disease 2019 (COVID-19) emerged in Wuhan city, China, in late 2019 and has rapidly spread throughout the world. The major route of transmission of SARS-CoV-2 is in contention, with the airborne route a likely transmission pathway for carrying the virus within indoor environments. Until now, there has been no evidence for detection of airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and this may have implication for the potential spread of the COVID-19. We investigated the air of patient rooms with confirmed COVID-19 in the largest hospital in Iran, on March 17, 2020. To collect the SARS-CoV-2 particles, ten air samples were collected into the sterile standard midget impingers containing 20 mL DMEM with 100 μg/mL streptomycin, 100 U/mL penicillin and 1% antifoam reagent for 1 h. Besides, indoor particle number concentrations, CO2, relative humidity and temperature were recorded throughout the sampling duration. | spa |
| dc.format.extent | 5 páginas | spa |
| dc.format.mimetype | application/pdf | spa |
| dc.identifier.doi | https://doi.org/10.1016/j.scitotenv.2020.138401 | spa |
| dc.identifier.issn | 0048-9697 | spa |
| dc.identifier.other | https://doi.org/10.1016/j.scitotenv.2020.138401 | spa |
| dc.identifier.uri | https://hdl.handle.net/20.500.12010/11558 | |
| dc.publisher | Science of the Total Environment | eng |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
| dc.source | reponame:Expeditio Repositorio Institucional UJTL | spa |
| dc.source | instname:Universidad de Bogotá Jorge Tadeo Lozano | spa |
| dc.subject | SARS-CoV-2 | spa |
| dc.subject | COVID-19 | spa |
| dc.subject | Outbreak | spa |
| dc.subject | Airborne | spa |
| dc.subject | Tehran | spa |
| dc.subject | Iran | spa |
| dc.subject.lemb | Síndrome respiratorio agudo grave | spa |
| dc.subject.lemb | COVID-19 | spa |
| dc.subject.lemb | SARS-CoV-2 | spa |
| dc.subject.lemb | Coronavirus | spa |
| dc.title | A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran | spa |
| dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | spa |
| dc.type.local | Artículo | spa |
Archivos
Bloque de licencias
1 - 1 de 1
Cargando...
- Nombre:
- license.txt
- Tamaño:
- 2.87 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: